80
ESF memory is full.
81
ECR is in communication with EFT terminal.
82
EFT terminal communication error: Press CL key.
83
Card data aborted by EFT terminal or ECR.
84
Enter voucher number printed on a receipt of EFT terminal.
85
EFT terminal is out of order.
86
Communication time out
99
It indicates that ECR data might be collapsed because of a low battery condition by battery discharge while ECR
is in stock for a long period.
Perform Physical RAM Test and Auto Preset, then leave ECR ON for minimum of 3 hours for battery charge.
MISCELLANEOUS MESSAGES
"Initial Reset" operation accepted
In PC batch communication
PC batch communication error
Transferring RAM data to peripheral (RAM data transfer)
Receiving RAM data from peripheral (RAM data transfer)
ADDITIONAL INDICATION FOR ESF
When the ESF memory is near full (5001 records out of 5696), the 2nd and 3rd MENU lamps will flash.
The ESF memory near full condition can be cleared by issuing the Z-79 report with data print by [SF-78.c], by taking Z-8879
by PC (from Tensai2000), or by taking Z-79 report by PC batch communication.
If the ESF memory becomes full, the data first stored, i.e. data at the beginning of the ESF memory area, will be deleted from
the ESF memory and the 2nd and 3rd MENU will flash continuously (only when [SF-78.b=0] is selected).